Building Designers need to account for the dead and live loads of fire sprinkler systems, in addition to the other load requirements imposed under the model building codes. Truss Designers are responsible for incorporating the additional load from the fire sprinkler systems into the truss design. The information in this Research Report is applicable to both floor and roof systems. Only vertical loads from fire sprinkler systems are discussed; lateral loads, where required, should be evaluated separately by a Registered Design Professional.
The repair and modification of metal plate connected wood trusses can be a very complicated subject, because each situation must be analyzed individually. This Research Report will give an overview of the fundamental principles behind truss repair that inform the truss designer’s approach in all truss scenarios.
The prescriptive residential energy code requirements found in the 2009, 2012 and 2015 International Residential Code (IRC) include requirements for continuous insulation at foundations in several climate zones. This Research Report discusses the issue of cantilevered sill plates supporting metal plate connected wood trusses installed parallel and perpendicular to the foundation walls where there is a potential for discontinuous planes between the exterior wall above the sill plate and the foundation insulation planes.
This Research Report provides a clear perspective on truss plant quality assurance and third party inspections as they relate to the requirements developed by the International Code Council (ICC) within the International Building Code (IBC) and the International Residential Code (IRC). The same perspective outlined in this Research Report should be applied when discussing how all structural building component third party inspections relate to Chapter 17 special inspection requirements.
A lay-on gable frame is typically connected from the top during truss placement, but after sheathing is installed, this connection is no longer visible for the building inspector to verify. This creates a need for an alternate connection that is visible from below. The goal of this Research Report is to analyze a simple, cost-effective, toe nail connection between the lay-on gable frames and supporting truss system that is visible after sheathing is installed.
A fire endurance rating may be mandated by code for many of the applications where trusses could be used in floor/ceiling, roof/ceiling or in attic separation applications. This Research Report discusses 5 different methods for determining fire resistance.
ASCE/SEI 7-10, Minimum Design Loads of Buildings and Other Structures, lists two methods for calculating wind pressures: Main Wind Force Resisting System (MWFRS) and Components & Cladding (C&C). This report will provide information to assist the building designer in deciding upon the appropriate analysis method for uplift due to wind loading.
It can be often misunderstood whether Truss Designers have the responsibility to seal a Truss Placement Diagram (TPD). The purpose of this Research Report is to provide the relevant code sections from the International Building Code (IBC) and the California Building Code for a thorough analysis and interpretation.
It can be often misunderstood whether a Truss Design Engineer has the responsibility to seal a Truss Placement Diagram (TPD). The purpose of this Research Report is to provide the relevant code sections from the latest editions of the International Building Code (IBC) for thorough analysis and interpretation.
The goal of this Research Report is to assist in designing safe buildings economically, especially when sprinkler systems are required or desired in the design.