Question: 

Our home has 2x4 roof trusses spanning 25 ft. spaced 16 in. O.C. Currently, there is limited attic storage on a plywood subfloor on the bottom chords, accessed via a small hatch in a closet. We would like to install a fold-down attic stair with a rough opening size of 25.5 in. x 54 in., with the long dimension perpendicular to the trusses. This would mean cutting the bottom chords of three trusses to frame the opening. Is this possible?

Question: 

What is the recommended standard spacing for open-web wood joists? I have seen them placed 24 in. O.C. Is this acceptable for a customer who will have an exercise room with 500 pounds of free weights? I understand there are problems with bouncy floors with 24 in. spacing. Is this true?

Question: 

I market 2x4 and 2x6 structural finger-jointed lumber. As of now, we have strictly sold it as a #2 product. However, we ran some through a bender at a sawmill to test the modulus of elasticity and it looks promising. The equipment showed no recognition of the joint; it acted like regular lumber. We would like to go forward with this venture in the hopes of offering an alternative MSR to solid lumber that may also be more cost effective. What do you need to have from us to get your approval?

Question: 

In a hip roof application where jack trusses connect to a girder truss using pressure blocking (power blocking), what is the proper installation and the span that is acceptable before a hanger is required?

Question: 

I have been hired by an insurance company to determine the extent of damage to roof trusses exposed to fire. How much fire damage compromises the structural integrity of the truss?

Question: 

I have mono trusses on either side of a firewall. I have the fire rating/wall material between them. Can I place a ridge vent above these two? Or should I use vents? How do I calculate the appropriate vent sizes and styles?

Question: 

Is the truss designer or the building designer responsible for calculating snow drift loads on a roof system?

Question: 

I am looking for information on point loading trusses. We manufacture mounting structures for solar panels. Typically, 10 to 15 sq. ft. of solar panel is supported by one standoff. Under extreme conditions – 50 lbs. per sq. ft. of wind load - we can transfer 500 to 750 lbs. of force onto one point of one truss. Are there any standards on this issue?

Question: 

What do you mean by the term “trusses”? Are there different kinds of trusses? What are their uses?

Question: 

I stamp the bottom chord of my trusses with my company name and the name of my third-party inspector. Recently, my local building inspector requested another stamp with the on-center spacing, the total design load and the load duration factor. I have never heard of this before and I was wondering if you had any further information on this requirement.